Custom Search
 
  
 
TM 55-1905-219-14-5
3-103. HYDROSTARTER PUMP (ENGINE-DRIVEN) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
6. Hand pump
a. Relief
Release the oil pressure
valve
in the system by opening
relief valve on side of
the hand pump about 1/2
turn.
WARNING
The oil pressure in the system must be released prior to servicing the pump
or other parts to prevent possible injury to personnel or equipment.
7.
Supply
a. Clean exterior dirt
hose
off.
b. Disconnect supply hose
(1) at swivel fitting
(2).
3-1784


 


Privacy Statement - Copyright Information. - Contact Us