TM 55-1905-219-14-5
3-106. HYDROSTARTER PIPING (AFT ENGINE ROOM) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1.
Hydro-
a. Check all pipes for
starter
leaks, damage, dents,
piping (1)
cracks or breaks.
b. Check all pipe
fittings. Make sure
they are tight and
do not leak.
2.
Reservoir
a. Check reservoir for
Refer to para-
(2)
leaks, dents, or
graph 3-107 for
cracks.
maintenance.
b. Check pipe connections
for leaks.
c. Check reservoir valve
for leaks, and damage.
3.
Accumu-
a. Check for leaks.
Refer to para-
lator
graph 3-102 for
(3)
b. Check for dents, or
replacement and
cracks.
Direct Support
Maintenance for
c. Check pipe connections
repair.
for leaks.
d. Make sure all fittings
are tight.
4.
Hydro-
a. Check for leaks.
Refer to para-
starter
graph 3-101 for
(4)
b. Check piping connec-
maintenance.
tions for leaks.
c. Check return, supply,
and pressure lines.
Make sure they are
tight.
5.
Pressure
a. Check gages for cracks
Refer to Direct
gages (5)
or broken glass.
Support Mainten-
ance.
3-1804
|
||