TM 55-1905-219-14-5
3-109.1. POWER DISTRIBUTION PANEL - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Panels
Power Dis-
a. Operate circuit
desig-
tribution
breakers to see if
nated
Panel
functioning properly.
L1--
b. Check exterior wires
and cables for signs
If defects are
of fraying or deter-
found, refer
ioration.
to Direct Sup-
port Mainten-
ance.
c. Check to see that in-
terior wiring and
cable connections are
tight.
WARNING
ALL SOURCES OF POWER MUST BE TURNED OFF before performing any
maintenance procedures. Failure to do so will result in severe injury or loss of life,
and major damage to the landing craft.
REPAIR
2.
Circuit
a. Remove screws (1)
breakers
from Power Distrib-
ution Box (2).
b. Remove front panel (3).
c. Tag and disconnect all
wiring.
d. Remove circuit
Discard.
breakers (4).
e. Install new circuit
breakers (4) and
secure.
f. Attach all wiring
and remove tags.
3-1830