TM 55-1905-219-14-6
3.123.1. SLACK CABLE INTERLOCK LIMIT SWITCH - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
d. Press-
Install.
fitted
lever (8)
e. Wire
1. Install slack cable
rope
interlock limit
guard
switch (6) into
tray (7)
chain guard tray (7).
2. Install mounting
screws (4) and
hex nuts (5).
3. Install wire rope
guard cover (3).
4. Insert capscrews
Tighten. Se-
(1) and hex nuts (2).
cure wire rope
guard cover on-
to wire rope
tray.
NOTE
Reconnect power to the winch and slack cable
interlock limit switch.
3-2093