Custom Search
 
  
 
TM 55-1905-219-14-6
3-136. TORQUE CONVERTER - MAINTENANCE INSTRUCTIONS (Continued)
LOCATION
ITEM
ACTION
REMARKS
SERVICE (Cont)
9.
Pressure
1. Operate engine
converter
gage
and check oil
(23)
pressure of 45
psi (310.3 kPa),
to 65 psi
(448.2 kPa).
2. Check for leaks.
REPAIR
10.
Fluid
a. Rear
1. Remove hose.
If necessary.
group
seal
drain
2. Remove elbows
hose
(25), and reducer
(24)
bushing (26).
b. Hose
1. Remove hose.
If necessary.
(27)