TM 55-1905-219-14-7
3-171.2.
CONNECTING ROD - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY
10. Orifice
Orifice
Install from the upper
Install orifice
(7)
bearing area.
0.3125 inch
(0.7938 cm)
from lower
surface.
11. Spray
Spray
a. Insert nozzle
Align holes in
nozzle
nozzle
straight into
spray nozzle as
(8) and
counterbore of
shown.
connecting
connecting rod.
rod
(3)
b. Support the con-
necting rod in
the arbor press.
Place a short 3/8
inch I. D. sleeve
on top of the
nozzle and press
the nozzle into
the connecting
rod until it
bottoms in the
counterbore.