Custom Search
 
  
 
TM 55-1905-219-14-7
3-174. INSTRUMENT PANEL - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
3.
Water
a. Clip
Remove.
temper
(13)
ature
gage
b. Adaptor
Remove.
(14)
c.
Nuts
Disassemble.
(15),
lock -
washers
(16),
and
gage
clamp
(17)
d. Gage
Remove.
(18)
e. Gage
Install.
(18)
f.
Gage
Assemble.
Incorrect cool-
clamp
ant temperature
(17),
readings will
nuts
be registered
(15)
if the gage
and
assembly is
lock-
incorrectly in-
washers
stalled or the
(16)
capillary tube
is damaged.
g. Clip
Install.
1. To prevent damage
(13)
to the gage assembly
from vibration, the
capillary tube must be
securely fastened
to the engine the
full length, with
suitable clips at
intervals of ten
inches (15 cm) or
3-3028


 


Privacy Statement - Copyright Information. - Contact Us