3-181. HYDROSTARTER PIPING - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (CONT)
4.
Hydro-
a. Check for leaks.
Refer to para-
starter
graph 3-176 for
(4)
maintenance.
b. Check piping connec-
tions for leaks.
c. Check return, supply,
and pressure lines.
Make sure they are
tight.
5.
Pressure
a. Check gage for cracks
Refer to Direct
gage (5)
or broken glass.
Support Mainte-
nance.
b. Check fittings and
connections for
tightness and leaks.
6.
Hand pump
Check for leaks.
Refer to para-
(6)
graph 3-179 for
maintenance.
7.
a. Check for leaks.
valve (7)
b. Check fittings. Make
sure they are tight.
8.
Filter and
a. Check for leaks.
gasket (8)
b. Check for cracks,
dents and wear.
9.
Valve ball
a. Check for leaks.
3000 lbs
(9)
b. Check for cracks,
dents and wear.
c. Check fittings for
tightness.