3-208. DIRECTIONAL CONTROL VALVE - MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
c.
Valve
1. Inspect for cracks
and leaking.
2. Insure that all
hardware is tight.
REMOVAL
2.
a. Screw
Remove.
(1),
identi-
fication
plate
(2)
b. Gasket
1. Lift to disconnect
and
ground screw (4).
wire
sub-
2. Tag and disconnect
assembly
external wiring.
(3)
3. Remove gasket and
wire subassembly (3).
c.
Piping
Disconnect piping at
union.
d. Recept-
Remove.
acle
(5)
e. Valve,
Remove from mounting.
Discard "O"
and
ring.
"O "
ring
(6)
3-3220


 