Custom Search
 
  
 
TM 55-1905-219-14-8
4-5. GENERAL (Continued).
Table 4-2. Portable Fire Pump (P-250) Carburetion Troubleshooting.
NOTE
Tables 4-1 thru 4-4 apply the Gale Marine P-250 portable fire pump. Tables 4-
1A thru 4-3A apply to the Prosser PE250 electric start portable fire pump.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.  Filter - fuel.
Step 1.
Clogged filter element.
Step 2.
Air leak due to faulty or misplaced filter bowl gasket.
Step 3.
Faulty fuel line connections.
2.
Fuel tanks.
Step 1.
Loose filler cap - faulty gasket.
Step 2.
Faulty fuel line connectors.
Step 3.
Clogged fuel line.
Step 4.
Leaks in fuel and air lines.
Step 5.
Pressure leaks in fuel tank.