Custom Search
 
  
 
TM 55-1905-219-14-8
4-5. GENERAL (Continued).
Table 4-2A. Portable Fire Pump (PE-250) - Running Troubles
NOTE
Tables 4-1A thru 4-3A apply to the Prosser PE250 electric start portable fire
pump. Tables 4-1 thru 4-4 apply the Gale Marine P-250 portable fire pump
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Lacks power.
Step 1.
Poor quality or improperly mixed fuel.
Empty fuel tank and refill.
Step 2.
Water in fuel.
Empty fuel tank and refill.
Step 3.
Exhaust port and/or muffler plugged.
Remove blockage from exhaust part and/or muffler.
Step 4.
Improperly adjusted carburetor.
Adjust carburetor, refer to paragraph 4-7.7A.
Step 5.
Ignition timing wrong.
Check ignition timing, refer to paragraph 4-7.10A.
Step 6.
Poor compression.
Replace engine, refer to paragraph 4-7.10A.
2. Runs unevenly.
Step 1.
Bad spark plug.
Replace.
Step 2.
Wrong spark plug.
Replace with correct spark plug.
4-21


 


Privacy Statement - Copyright Information. - Contact Us