Custom Search
 
  
 
TM 55-1905-219-14-8
4-7.5. MAGNETO ASSEMBLY - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
ADJUSTMENTS (Cont)
(4) Turn the adjusting screw B to right or left to obtain desired gap opening.
When correct, both faces of the gage strip should bear slightly against both
breaker point faces and should neither be too tight or too loose.
(5) Tighten the anchor screw A securely. Repeat as above to adjust gap of
other breaker point set.
A
Anchor screw
B
Adjusting screw
REMOVAL
5. Flywheel
a. Nut and
Remove.
cap assembly
(6)
b. Crank-
Remove.
shaft
nut (7)
Remove the
flywheel nut by
striking the handle
of a socket
wrench sharply
with a mallet or
small hammer.
4-165


 