TM 55-1905-219-14-8
4-7.5. MAGNETO ASSEMBLY - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
f.
Ignition
1. Insulation.
Coat end of
lead (25)
lead liberally
with DC-4 or
equivalent.
2. Force end of ignition
lead into coil tube
with the needle pene-
trating stranded core
of the lead.
g. Coil
Position and insert
Tighten to hold
(14)
screws.
snugly but not
with
tight.
ignition
lead
attached,
screws
(21), and
flat
washers
(22)
NOTE
Note machined bosses on armature plate casting and adjust position of the coil
to where face of the coil heel rests flush with the face of the machined boss.
4-172