4-7.5A. PRIMING PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
NOTE
If fan belt shows signs of wear or proper tension cannot be obtained, replace fan
belt as follows:
d. Screws (43)
Remove.
e. Retractable
Remove.
starter (44)
f. Fan pulley
Hold while removing
Use spanner
(45)
nut (46) and washer
wrench.
(47).
g. Screws (48),
Remove.
and lock-
washers (49)
h. Starter
Remove.
pulley (50)
i. Fan belt
Replace.
(25)
j. Starter
Install using screws
pulley (50)
(48), and lockwashers
(49).
k. Washer (47),
1. Install.
and nut (46)
2. Tighten to 35 lb-ft
(47.5 Nm) torque.
l. Belt
Recheck and adjust per
tension
step 7c.