4-11.2 FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS. 
This task covers: 
a. Inspection 
b. Disassembly 
c. Reassembly 
INITIAL SETUP 
Test Equipment 
References 
NONE 
NONE 
Equipment 
Special Tools 
Condition 
Condition Description 
Paragraph 
Hammer - soft 
Fresh Water Pump Set 
Screwdriver 
removed 
Spanner wrench 
Torque wrench 
Material/Parts 
Special Environmental Conditions 
Preformed packing 50718 
NONE 
Seal assembly 43008 
Personnel Required 
General Safety Instructions 
2 
NONE 
LOCATION 
ITEM 
ACTION 
REMARKS 
INSPECTION 
1. Pump 
a. Casing 
Inspect for breaks, 
cracks, or leaks. 
b. Hardware 
Inspect for tightness. 
DISASSEMBLY 
2. 
a. Screws (1) 
Remove. 
b. Head (2) 
Remove. 
Strike with soft 
hammer. 
c. Prefromed 
Remove 
Discard packing. 
packing (3) 
4-542 
 | 
			||
![]()  | 
		||