TM 55-1905-219-14-8
4-11.4. FRESH WATER PUMP CONTROLLER - MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR
3. Push-
a. Wiring
Tag and disconnect.
button
switches
b. Retaining Unscrew and remove.
nut (5)
c. Identi-
Remove.
fication
plate
(6), and
switch
(7)
d. Switch
Install.
(7),
identi-
fication
plate
(6), and
retaining
nut (5)
e. Wiring
Reconnect.
4. Fuses
Fuses (8)
Remove and replace.
5. Fuse
a. Wiring
Tag and disconnect.
block
b. Screws
Remove.
(9)
c. Fuse
Replace.
block
(10)
d. Screws
Replace.
(9)
e. Wiring
Reconnect and remove
tags.
6. Selector
a. Wiring
Tag and disconnect.
switch
b. Setscrew
Loosen.
(11)
c. Knob (12)
Remove.
4-560