TM 55-1905-219-14-8
4-16.1. SEWAGE PUMP SET - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
In order to eliminate possible shock and injury, tag and place disconnect switch in the
OFF position, and pull fuses as an added safety precaution.
REMOVAL
1. Wiring
a. Screws (1),
Remove.
and cover
(2)
b. Wiring
Tag and disconnect.
2. Piping
a. Union (3)
Disconnect.
b. Nuts (4),
Remove.
lockwasher
(5), and
screws (6)
c. Flange (7)
Separate.
3. Pump set
a. Nuts (8),
Remove.
(9), and
screws (10)
b. Pump set
Remove.
INSTALLATION
4. Pump set
Screws (10),
Install.
(9), and
nuts (8)
5. Piping
a. Flange (7)
Align flange sections.
b. Screws (6),
Install.
(5), and
nuts (4)
c. Union (3)
Reconnect.
4-628
|
|