Custom Search
 
  
 
TM 55-1905-219-14-8
4-16.3. SEWAGE PUMP MOTOR - MAINTENANCE INSTRUCTIONS.
This task covers:
a.
Inspection
c.
Disassembly
e.
Installation
b.
Removal
d.
Reassembly
INITIAL SETUP
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition
Condition Description
Paragraph
Bearing puller
Sewage Pump Set removed
Sewage Pump removed
Material/Parts
Special Environmental Conditions
Grease Type GAA
NONE
(MIL-G-10942)
Personnel Required
General Safety Instructions
1
Observe WARNINGS
LOCATION
ITEM
ACTION
REMARKS
In order to eliminate possible shock and injury, tag and place disconnect switch in the
OFF position, and pull fuses for added safety precaution.
INSPECTION
1. Motor
a. Wiring
Inspect for breaks,
cracks, and defective
insulation.
b. Frame
1. Inspect for breaks,
cracks, and signs of
damage.
2. Check for unusual
noise and vibration.
4-643


 