Custom Search
 
  
 
TM 55-1905-219-14-8
4-16.3. SEWAGE PUMP MOTOR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
k. Bearing
Remove.
Bearings should be
(16)
remove with bearing
pullers using a
center insertion in
the end of the shaft
to protect the shaft
center. If a
puller is not avail-
able, use a fiber
hammer and transmit
blows through a hard
wood block.
l. Winding kit
Remove from body
Disconnect wiring.
(17)
(18).
m. Screws (19),
Remove.
and capaci-
tor housing
(20)
n. Capacitor
Remove.
Disconnect wiring.
(21)
REASSEMBLY
a. Capacitor
Reassemble.
Reconnect wiring.
(21), hous-
ing (20),
and screws
(19)
b. Winding kit
Reinstall in body
Reconnect wiring.
(17)
(18).
c. Bearing
Reinstall.
To reinstall ball
(16 and 15)
bearings, either in
a press or on the
bench, pressure
should be applied
to the inner race
by using a square
faced sleeve or
piece of pipe that
will fit over the
shaft, to avoid
damaging the bearing.
4-646


 