Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-8
4-17.2.
MACERATOR/TRANSFER PUMP - MAINTENANCE INSTRUCTIONS.
This task covers:
a. Inspection
b. Repair
c.
Adjustment
INITIAL SETUP
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
Paragraph
Packing puller
Pump set removed
Plastic hammer
Material/Parts
Special Environmental Conditions
Oil (MIL-L-2104 Type
NONE
OE/HDO 20)
Oil Hydr-O-Matic-submersible
Personnel Required
General Safety Instructions
1
Observe WARNINGS in paragraph
LOCATION
ITEM
ACTION
REMARKS
In order to eliminate possible shock and injury, tag and place disconnect
switch in the OFF position, and pull fuses for an added safety
precaution.
INSPECTION
1. Pump
Housing
a. Inspect for breaks,
cracks, and dents.
b. Inspect for leaking.
c.
Inspect for loose
Do not tighten
hardware.
until after
adjustments in
step 4.
4-665
|
||