Custom Search
 
  
 
TM 55-1905-219-14-8
4-19. TOILET - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
SERVICE (Cont)
b. Mechanical
Lubricate.
Use a water
linkage
insoluable
grease
(Lubriplate).
c. Checks
Refer to step 11.
REMOVAL
3.
In order to prevent electrical shock and possible
death, tag and disconnect circuit breaker on con-
trol circuit, and pull fuses as an added precaution.
a. Two nuts
Remove.
(1), flat-
washer (2),
and screws
(3)
b. Switch (4),
Remove from bracket
and gasket
(6).
(5)
c. Wiring
1. Tag, disconnect and
Refer to sche-
cover exposed ends
matic in para-
with electrical
tape, or wire nut.
2. Turn on circuit
breaker in order to
continue use of the
system.
d. Flush valve
Shut off water.
Refer to para-
(7)
e. Nut (8),
Remove.
and screw
(9)
f. Clevis fit-
Remove from flush
ting (10)
valve.
4-708


 