Custom Search
 
  
 
TM 55-1905-219-14-8
4-19. TOILET - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
6. Switch
In order to prevent electrical shock and possible
death, tag and disconnect circuit breaker on con-
trol circuit, and pull fuses as an added precaution.
a. Two nuts
Remove.
(1), flat-
washers
(2), and
screws (3)
b. Switch (4),
Remove from bracket
and gasket
(6).
(5)
c. Wiring
Disconnect.
Refer to sche-
matic in para-
graph 4-15.
d. Switch (4)
Replace.
e. Wiring
Reconnect.
Refer to sche-
matic in para-
graph 4-15.
f. Gasket (5),
Align holes with
and switch
bracket (6).
(4)
g. Two screws
Install.
(3), flat-
washers
(2), and
nuts (1)
4-714


 