TM 55-1905-219-14-9
4-75. HIGH INTENSITY LIGHT - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
e. Wiring
Inspect for worn or dam-
aged wiring.
2. Battery
a. Fuse
Inspect for blown fuse.
Charger
b. Switches
Inspect for proper oper-
ation.
c.
Cables
Inspect for breaks,
cracks, and signs of
damage.
d. Case
Inspect for dents and
signs of damage.
TEST
3. Light
Test light for proper operation, and brilliance of
lamp over an extended period of time.
4. Battery
Plug into light. Check that the battery charger
charger
will maintain the charge level of the light.
5. Battery
Check for specific gravity of at least 1260.
REPLACE
6. Light
a. Lamp
1. Disconnect wiring and
replace.
2.
Reconnect wiring.
3. Test.
b. Battery
1. Disconnect wiring and
replace.
2. Reconnect wiring.
3. Charge battery for at
least 24 hours.
4. Test light.
4-1453