TM 55-1905-219-14-9
4.77.4. SEARCHLIGHT - DRUM ASSEMBLY - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPLACE (Cont)
d. Loose socket
Tighten.
clamps (10)
e. Lamp (11)
Pivot in other
socket until the
loose socket is
centered within
its confined free-
dom.
f.
Socket
Tighten remaining
clamp (10)
clamp.
g. Lamp (11)
Focus.
Focus of the search-
light is fixed at
the time of manufac-
ture and under
ordinary conditions
should not be
changed. Focus can
be changed by loosen-
ing the three screws
(12) and moving the
entire lampholder on
adjustable support
(13) as required to
center the filament
of the lamp in the
axis of the reflec-
tor. Project the
light beam on a
screen or vertical
surface a minimum
distance of 55 feet
(16.8 m) away and
move the adjustable
base forward and
backward until the
smallest and
clearest image
of the filament
appears. Tighten
all screws.
4-1526