Custom Search
 
  
 
TM 55-1905-220-14-1
Legend for Figure 2-7 (Continued)
11. STEERING LEVER - Steers vessel in HAND or NFU settings of Steering Selector Switch: Clockwise for Right
Rudder- counter-clockwise for Left Rudder.
12. FLANKING CONTROL FUSE - Fuse 5 amp. - Circuit protection for flanking control circuits.
13. POWER AVAIL - PUMP RUN - tights indicating flanking pump running or available to run.
14. FLANKING PUMP START/STOP - Pushbuttons to turn the Flanking pump on/off .
15. FLANKING SELECTOR - LEFT HAND - MIDSHIPS - RIGHT HAND -Selector-switch and lights indicating position of
flanking rudders. (Used only during maneuvering).
16. AUTOMATIC STEERING ADJUSTMENT RATE MULTIPLIER - Controls sensitivity to changes in pre-set steering.
Clockwise maximum sensitivity. Counter-clockwise minimum sensitivity (50 % of maximum).
17. WEATHER ADJUST - Controls the amount of heading error permitted before rudder responds to changes.
Calm seas - Set to 0
Rough seas - Set to number of degrees (5
maximum yaw motion from basic
heading.
18. INTERGRATOR SWITCH - ON/,RESET - In the ON position a continuous average heading error signal is computed.
19. RUDDER MULTIPLIER - Provides operator control of the rudder ratio. -High settings cause the ship to respond
quickly to course error by ordering larger rudder angles.
20. RUDDER LIMIT - Sets limit of rudder movement right or left, 5 to 45 degrees.
Figure 2-7. Steering, Control Panel (Sheet 2 of 2)
2-12


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business