Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-1
Legend Figure 2-65.
1.
SYSTEM START/STOP - Pushbutton start and stop switches.
2.
POWER ON/SYSTEM ON (GREEN) - Power on is lit when disconnect switch is in the ON position.
System on is lit when the START switch is pressed.
3.
DISCONNECT - Disconnects power from the systems.
4.
TANK LEVEL FULL (RED) / EMPTY (GREEN) - Liqhts indicating level of tank contents.
5.
SUM ALARM (RED)/RESET - Light indicating tank level almost over full
6.
VACUUM PUMP OVERRUN (RED) - Vacuum pump timer cycle over and pressure cannot be held.
7.
OVERBOARD DISCHARGE PUMP/START JOG - Press to momentarily run pump to lower tank level
to tank empty Ievel.
8.
VACUUM PUMP #1 AUTO/OFF -. Turns on/off a vacuum pump.
9.
VACUUM PUMP #2 AUTO/OFF - Turns on/off a vacuum pump.
10.
MOTOR RUN (AMBER) OVERLOAD (RED) RESET - Amber light-motor is running. Red light-
motor is stopped. Press to reset motor.
11.
OVERBOARD DISCHARGE PUMP - Status lamps and reset button.
12.
VACUUM PUMP #1 - Status lamps and reset button.
13.
VACUUM PUMP #2 - Status lamps and reset button.
Figure 2-65. Sewage System Control Panel (Sheet 2 of 2)
2-58
|
||