Custom Search
 
  
 
TM 55-1905-220-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item To Check/
Not Mission
No
Interval
Service
Procedure
Capable If :
139
QUARTERLY
Engine Room
POWER GENERATOR. Check the
Low oil level.
oil level in the sight gage (60). Add
oil, (MIL-L-9000H (SH)) if necessary,
to maintain the oil level to the line on
the sight gage. Do not overfill. After
adding oil, run engine for several
minutes. Then shutdown engine and
recheck oil level.
Change the oil by removing oil plug
(61) from the sight gage. Use oil
(MIL-L-9000H (SH)).
140
QUARTERLY
Engine Room
BILGF PUMP (Electric) Lubricate
Bilge pump
fittings (1) with grease (MIL-G-24139A
fails to function.
(SH)), with pump running.
Change 5