Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item To Check/
Not Mission
No
Interval
Service
Procedure
Capable If :
170
ANNUAL
Engine Room
HYDROSTARTFR FILTER.
Filter
obstructed.
CAUTION
Do not attempt to change
filter element until the
pressure in the system is
released.
Release pressure by loosening relief
valve (53) on the hand pump (54).
Loosen bail nut (55) and swing bail
(56) aside. Remove cup (57), filter
(58) and gasket (59). Discard filter
and gasket. Clean cup (57) with
compressed air.
Reinstall in reverse order.
WARNING
Use eye protection when
using compressed air.
Change 5
2-224


 