174
ANNUAL
Engine Room
HYDROSTARTER SYSTEM. Refer
to Table 2-1 for maintenance on the
Hydraulic Reservoir.
Remove the Hydrostarter from the
Generator for lubrication. Before
removing the Hydrostarter release
the pressure in the system by means
of the relief valve (37) on the hand
pump (38). Then remove three bolts
(39) and washers (40) that attach
starting motor (41) to the flywheel
housing. Remove the starting motor
without disconnecting the hydraulic
hoses.
Apply grease (MIL-G-24139A (SH))
on drive clutch pinion (42) to make
sure clutch will slide freely while
compressing spring. Also apply
grease to the fingers of dutch fork
(43) and on the spool of clutch yoke
(44).