Custom Search
 
  
 
TM 55-1905-220-14-10
5-22. ACCUMULATOR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
SERVICE
a. Accumu-
Clean all exterior dirt
lator
from accumulator and
(1)
protective cap covering
air valve assembly (14).
b. Recharg-
1. Attach gage (28) end
ing the
of charging kit to
accumu-
valve (33) on nitrogen
lator
tank.
2. Remove protective cap
from air valve assem-
bly (14).
3. Install air valve stem
extension (29) on the
air check valve (15).