Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-10
5-22. ACCUMULATOR - MAINTENANCE INSTRUCTIONS (Continued)
LOCATION
ITEM
ACTION
REMARKS
SERVICE (Cont)
8. Back off the shaft pin
Isolates the
in air check valve
pressure in the
connector (30).
charging hose
kit.
Tighten hex locknut
(13) on accumulator
valve stem.
WARNING
Bleed off pressure before disconnecting nitrogen tank and charging hose kit.
9. Depress the bleed-
Release pres-
off valve (34) on
sure to zero.
the pressure gage.
10. Disconnect the accum-
lator charging kit.
(a) From accumulator.
(b) From nitrogen tank.
11. Replace the protective
cap on the air valve
assembly (14).
5-410
|
||