5-24. HYSROSTARTER SOLENOID-MAINTENANCE INSTRUCTIONS.
This task covers:
a. Disassembly
b. Reassembly
INITIAL SETUP:
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition
Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
NONE
NONE
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY
a. Manual
1. Loosen wing nut
control
(1).
screw
2. Unscrew manual
control screw (2)
from solenoid
housing (3).
3. Remove lockwasher
(4).
4. Remove wing nut
(1).
5-426


 