5-24. HYSROSTARTER SOLENOID-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
b. Solenoid
1. Remove screws (6),
housing
lockwashers (7),
from retainer
plate (8).
2. Remove solenoid
Solenoid valve
valve (9) and re-
replace, if
tainer plate (8)
necessary.
from solenoid
housing (3).
3. Stop screw (10),
Do not loose
flatwasher (11),
ball.
and ball valve
(12)
c. Actuator
1. Remove housing
Discard gaskets.
Housing
(13), O-ring
gasket (14),
and valve spring
(15) from solenoid
housing (3).
2. Remove poppet
Discard gaskets.
valve (16), O-ring
gasket (17), solen-
oid valve body (18),
and O-ring gasket
(19) from solenoid
housing (3)
5-428
|
||