5-32. GENERATOR (40 KW)-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
o. Wiring
1. Route wiring through
frame and reconnect.
p. Terminal
Install.
On both sides.
box covers
(8), and
screws (7)
q. Fan and
Install.
driving
disc (12)
NOTE
If spacers were removed during disassembly. Make sure they are reinstalled.
r.
Screws
Install.
(10), and
(11)
s.
Pipe plug
Install.
(9)
t.
Oil level
Fill with oil.
Use type OE/HDO.
sight gage
(40)
5-515
|
||