TM 55-1905-220-14-10
5-43. CYLINDER BLOCK - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECT (Cont)
d. Check the cylinder block bores:
(1) Visually check the contact area as revealed by the honed surface. There must
not be any low spots which are larger in area than a half dollar.
(2) Measure the entire bore of each cylinder with cylinder bore gage J5347 which
has a dial indicator calibrated in .0001 inch increments. The standard block
bore is 4.6260 inch to 4.6270 inch.
(3) First, place the bore gage in the master ring gage J8386-01 which has an I.D.
of 4.6270 inch and set the dial to zero. Next, rotate the dial clockwise .0005
inch to give a zero dial indicator setting of 4.6265 inch. Take measurements
on the cleaned-up surface only at positions A, B, C, D, E, and F in the bore on
axes 45apart. Read the measurements from the zero mark on the gage.
5-632