Custom Search
 
  
 
TM 55-1905-220-14-11
5-71. BLOWER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
OVERHAUL-TIMING BLOWER ROTORS (Cont)
e. The clearance between the rotor
lobes may be checked with 1/2"
wide feeler gages in the manner
shown below. When measuring
clearances of more the .005",
laminated feeler gages that are
made up of .002", .003" or .005"
feeler stock are more practical
and suitable than a single feeler
gage. Clearances should be
measured from both the inlet
and outlet sides of the blower.
f.
TIME THE ROTORS AS FOLLOWS:
Time the rotors to have from
.002" to .006" clearance between
the TRAILING edge of the right-
hand helix rotor and the LEADING
edge of the left-hand helix rotor
measured from both inlet and out-
let sides as shown above.