Custom Search
 
  
 
TM 55-1905-220-14-11
5-94.
HYDRAULIC CYLINDER - STERN GATE - MAINTENANCE INSTRUCTIONS
(Continued)
LOCATION
ITEM
ACTION
REMARKS
REPAIR - (Cont)
c. Cylinder
Drain fluid by manually
Compressed air may
cycling cylinder.
be used to remove
hydraulic fluid,
if above warning
is followed.
d. Clevis (1),
Remove from piston
cotter pin (2),
rod (21).
and pivot pin
(3)
e. Capscrews (5)
Unscrew and remove
retainer plate (6).
(4)
f. Rod cartridge
Remove from
(8)
head (10).
g. Rod bearing
Disassemble
(8A), rod wiper
cartridge.
(8B), "0" ring/
"U" cup packing
(8C), rod backup
ring (8D), "0"
ring (8E), back-
up ring (8F)
h. Tie rod lock
Remove from tie
nuts (9)
rod (23).
i. Head (10) and
Remove from
cap (26)
cylinder (22).
j. Exactajust drive
Remove. Do not
screw (11), cover
damage components.
(12), needle and
check valve (13),
and needle valve
ring (13A)
k. Tie rods (23)
Remove
l. End cover "O"
Remove from head
ring (14) and
(10) and cap (26).
backup ring (15)