5-97. HYDRAULIC CONTROL AND FLOW CONTROL MANIFOLD - MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
Repair (Cont)
Discard O-ring
1. Remove from body
i.
Retainer
seals (21 and
(3)
seal.
22).
plugs
2. Replace defective
(20),
parts.
O-ring
seals
3. Replace O-ring seals.
(21 and
22),
4. Reassemble.
seal
retainers
5. Insert in body (3).
(23),
spool
springs
(24),
and
spool
(25)
Install.
j.
Retaining
rings
(19),
end cap
(18),
and
screws
(17)
k.
End cap
Place over cap.
clamp
(12)
l.
Control
Align holes and insert
lever
spring pin.
(8),
spring
pin (7),
detent
stem
(15),
and
end cap
(13)