5-112. RUDDER ANGLE TRANSMITTER - MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
OVERHAUL (Cont)
5.
Limit
a. Wiring
Disconnect wires to
Switches
defective switch.
(outside-
inside)
b. Nuts (31),
Remove top nuts on both
lock-
threaded rods (33), and
washers
remove two rods.
(32),
and
threaded
rods
(33)
c.  Switch
Replace defective
(34)
switch.
d. Threaded
Install.
rods
(33),
(32),
and
nuts
(31)
e. Wiring
Reconnect.
f.  Switches
Adjust.
Refer to Step 9.
6.
Terminal
a. Wiring
Tag and disconnect.
Strip
b. Screws
Remove.
(35),
and
lockwasher
(36)
c.
Terminal
Replace.
strip
(37) and
identi-
fication
strip (38)
5-1268


 