Custom Search
 
  
 
TM 55-1905-220-14-11
5-147. REFRIGERATOR/FREEZER - MAINTENANCE INSTRUCTIONS (Continued).
REPLACE (Cont)
(a) Close liquid service valve, run compressor and pump refrigerant into receiver tank until zero (0) lbs pressure
reading is obtained on low side pressure gauge, then close suction service valve. On capillary tube system, purge, (let
out) entire refrigerant charge from the system.
(b) Remove dehydrator from liquid line, install new dehydrator, charge system, and check for leaks.