Custom Search
 
  
 
TM 55-1905-220-14-11
5-148. MILK DISPENSER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
i. Screws
Remove.
(24)
j. Molding
Remove.
closure
(25),
and
filler
block
(26)
k. Lowside
Pull straight down to
assembly
clear spacers (27 and
(22)
28).
l. Evapora-
1. When evaporator tube
tor tube
leak is detected, cut
repair
plastic loose from
between tube and
liner, and, if
necessary, break
solder joint loose.
2. Pull tubing free of
liner. Use tube
cutter to cut tube
on each side of
leaking area. Cut
new tube sightly
longer than removed
tube to allow for
swedging. Swedge
both ends of tube.
3. Install new section
of tube in evaporator
line. Braze tubing
connections with
brazing rod (United
Wire and Supply
Company, Phoson No.
6 or equivalent).
5-1546


 