Table 3. Public Address Set Type AN/PIC-2, Troubleshooting -
Voltage Measurements.
From
Test
Component
Normal Indication
Point
Symbol
No Signal
D.C. Volts Full Signal
B
ACROSS R1
0
0
B
ACROSS R3
+0.2
+0.2
B
ACROSS R4
+0.08
+0.08
A
ACROSS R2
-12
- 11.5
A
ACROSS R5
-0.45
-0.45
A
ACROSS R6
-0.35
-0.35
A
To T1-1
-0.25
-0.25
A
To T1-4
-0.45
-0.45
A
To T2-3
-0.1
+0.15
A
To T2-5
-0.1
+0.15
B
To L1-1
Below 0.05
+0.3
B
To L1-3
Below 0.05
+0.3
Conditions of Test
Meter: Any standard 20,000 ohm/volt VOM
Test Point A - Positive bus
Test Point B - Negative bus
Transistors in circuit
Test set-up (see illustration)
All readings are in volts