2-30. PROPULSION ENGINE - WARM WEATHER - LOCAL STARTING (Cont).
c.
Pressure gages (4 and 5) should read:
AMBIENT TEMPERATURE
GAGE READING
Above 40 (4 4C)
F
1500 psi (1054.5 kg sq cm)
40F to 0 (4.4C to -17.8 )
F
C
2500 psi (1757.5 kg sq cm)
Below 0 (-17.8 )
F
C
3300 psi (2319.9 kg sq cm)
d. Operate hand pump (6) on hydrostarter in aft engine room to change accumulators (7 and 8).
e. Pressure gages (9 and 10) should read:
AMBIENT TEMPERATURE
GAGE READING
Above 40F (4.4 )
C
1500 psi (1054.5 kg sq cm)
40F to 0F (4.4 to -17.8 )
C
C
2500 psi (1757.5 kg sq cm)
Below 0 (-17.8 )
F
C
3300 psi (2319.9 kg sq cm)
2-356