Custom Search
 
  
 
TM 55-1905-220-14-2
2-74. FRESH WATER SYSTEM (Cont).
d. The procedure consists of:
filling the system
placing system in operation (automatically)
operating the system on dockside water
shutting off the system
e. The system overview FO-37 shows the relationship of the various components. In addition, the lettered points
are to clarify the various figures in the text.
f. To fill system with water:
(1)
Port Side (Frame 44).
(a) Attach hose (1) located in hose cabinet (2) on the side of the bulkhead to fill valve (3).
(b) Open fill valve (3) by rotating valve counter-clockwise.
(2)
Equipment and Repair Parts Stores Compartment.
(a)
Open shut off valve (4) by rotating valve counter-clockwise se.
(b)
Check that multi-relief valve (5) is closed.
(c)
Check that dockside water valve (6) is closed (full clockwise).
(d)
Fill tank with water. At 95% capacity the tank holds 3,958 gallons (14981 liters) of water.
2-493


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business