TM 55-1905-220-14-2
2-74.
FRESH WATER SYSTEM (Cont).
(4)
Forward Engine Room.
(a)
To Start the Pressure Pump.
1
Place circuit breaker #5 on power distribution panel (P401) in the ON position.
2
Press START switch (28) on fresh water pump controller.
3
The pump will run.
4
Check the system for open spigots, hose connections and leaks.
5
Both the cold water and hot water tanks will fill.
6
Open each spigot and hose connection. L t any trapped air escape. When water runs shut the spigot or
e
hose connection.
7
Observe the pump. An automatic control will shut the pump off.
NOTE
The pump should run only when a tank requires fitting, or a spigot or hose connection is
open. If the pump does not shut off, check the system.
2-499