TM 55-1905-220-14-2
2-74.
FRESH W;.TER SYSTEM (Cont).
(c)
To Operate the System on Dockside Water:
The system can be operated on dockside water while in port. The procedure is the same as the previous
procedure with the following exceptions:
1
Do not press the START switch (28) on the fresh water pump controller.
2
Close shut off valve (4) by rotating valve clockwise.
3
Close pressure tank shut off valve (13) by rotating the valve clockwise.
4
Open dockside water valve (6) by rotating valve counterclockwise.
CAUTION
Check the dockside water pressure. Too much pressure could break a hose, or blow a
fitting, gasket, or washer. Maximum pressure should be 60 psi (412.7 kPa)
(d)
To Shut the System Off:
1
Place circuit breaker #6 on power distribution panel (P-401) in the OFF position.
2
Press the STOP switch (29) on the fresh water pump controller.
3
Place circuit breaker #5 on power distribution panel (P-401) in the OFF position.
4
Close supply valves as required.
2-501


 