2-87. DRAINING BILGE WITH BILGE PUMP (Cont)
b. To operate the bilge pump, refer to FO-42 and proceed as follows:
c.
Refer to paragraph 2-94 for the method of draining the bilge using both the bilge pump and the fire pump.
(1)
Aft Engine Room.
Place flow control valve (1) in the off position.
(2)
Forward Engine Room.
(a) Place flow control valve (2) in the on position.
(b) Place flow control valve (3) in the on position.
(c) Rotate the overboard discharge check valve (4) clockwise.
(d) Rotate the remote control valve (5) counter-clockwise.
(e) The port propulsion engine must be running. The clutch on the marine gear can be in any position.
(f) Pull out knob (6) on local throttle control (7).
(g) Rotate knob (6) one-quarter turn counter-clockwise.
2-530


 