2-121. HALON SYSTEM ALARMS (Cont).
2-121. HALON SYSTEM - REACTIVATION.
The following procedure is for clean up and reactivation of the Halon system after a fire.
Do not enter compartment if hatch or bulkhead
feels hot to the touch, as fire
might be smoldering.
Before entering compartment, put
on oxygen breathing apparatus.
Before clean-up can be started, make
sure Halon extinguishing agent
is exhausted from the area.
a.
Open engine room access hatch.
b.
Open engine room scuttle.
c.
Open flammable liquids storeroom door.
d.  Check all electrical wiring in the damaged compartment for breaks, bare spots, or charred
insulation. Replace if physical damage is present.
e.  Check plumbing in compartment for breaks, loose connections, and general usability.