Observe the control pressure gage (16) on the hydraulic tank assembly (17). Normal control pressure is
365 to 370 psi (25771.6 to 26114.6 gm sq cm). Minimum allowable pressure is 350 psi (24712.5 gm s
l.
Observe operating pressure gage (18) on hydraulic tank assembly (17). Normal operating pressure is
600 to 800 psi (42364.2 to 56485.6 gmsq cm). Minimum allowable pressure is 600 psi (42364.2 gm sq. cm).
m. When prolonged idling is needed, maintain at least 800 RPM minimum.