Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-3
Table 3-6. Propulsion Engine - Excessive Crankcase Pressure
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Excessive exhaust back pressure.
Step 1.
Check for excessive muffler resistance.
Refer to Direct Support Maintenance.
Step 2.
Check for faulty exhaust piping.
Check the exhaust back pressure. Refer to Direct Support Maintenance.
Table 3-7. Propulsion Engine - Low Oil Pressure Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Make checks with minimum water outlet temperature of 160F (71C).
o
o
An alarm will sound in the pilot house.
1.
Lubricating oil.
Step 1.
Check for suction loss.
Check the oil and bring it to the proper level on the dipstick.
Step 2.
Check lubricating oil viscosity.
Use the recommended grade and viscosity of oil.
3-49
|
||